Data Center Technician L2

NTT Global Data Centers

Illinois, US$78k–146k/yr
Full time$78k–146k/yrAssociatesMid levelIn personData Center Operations And Critical Facilities Infrastructure5,001+ employees

On-site Data Center Technician L2 responsible for maintaining critical mechanical, electrical, and fire life safety systems in a 24/7 data center environment.


About this role

NTT Global Data Centers is seeking a mid-level Data Center Technician L2 to operate, monitor, maintain, and troubleshoot critical mechanical, electrical, fire life safety, and building monitoring systems. The role requires an associate-level qualification or equivalent experience, at least three years of critical-facilities experience, relevant safety certifications, physical capability, and willingness to work on-site shifts and after-hours escalation coverage.

Required qualifications

  • An Associate of Science in Technology degree or equivalent education and work experience is required for the L2 role.
  • At least 3 years of experience in a mechanical or electrical position within a critical-facilities environment is required.
  • Candidates must have a high school diploma or GED.
  • Candidates must obtain CPR, First Aid, and NFPA 70E certification during employment.
  • Candidates must possess an OSHA-approved forklift certification or be able to obtain one after hire.
  • Candidates must understand data center mechanical, electrical, fire life safety, and building monitoring systems.
  • Candidates must have hands-on experience installing, maintaining, or troubleshooting large commercial or industrial systems.
  • Candidates must be able to read blueprints, schematics, diagrams, and technical orders.
  • Candidates must be able to operate hand tools, machine tools, electrical testing equipment, and forklifts.
  • Candidates must be able to analyze problems, multitask, communicate effectively, and work in a process-driven team environment.
  • Candidates must be willing to work shifts that may include nights, holidays, weekends, and after-hours escalation coverage.
  • Candidates must be able to work on-site because telecommuting is not permitted.
  • Candidates must be able to lift and carry equipment weighing up to 50 pounds and climb ladders or work on raised platforms.

Desired qualifications

  • Experience in a data center, hospital, semiconductor facility, or power plant is preferred.
  • Experience with chilled-water systems, centrifugal chillers, cooling towers, HVAC, CRAC/CRAH units, and humidification systems is preferred.
  • Experience with generators, switchgear, transformers, UPS systems, ATS, STS, PDU, and critical-power distribution is preferred.
  • Knowledge of NEC, NFPA 70E, NFPA 72, NFPA 25, OSHA requirements, and applicable building codes is preferred.
  • Experience with BMS, PLC controls, data trending, critical monitoring systems, and preventive or predictive maintenance is preferred.
  • Proficiency with Microsoft Office applications is preferred.

Restrictions

  • The role must be performed on-site, with no telecommuting permitted.
  • The position requires shift work, including possible nights, holidays, weekends, and after-hours notification or escalation coverage.
  • The work environment may involve varying temperatures, loud noise, ladders, raised platforms, and heavy equipment.
  • Employees must wear leather close-toed shoes with solid rubber soles.

Similar jobs

Find your dream job with Sprout

Swipe right to apply. Let AI handle the rest.