Mechanical Engineer, Data Centers - Remote (U.S.)

AECOM

Arlington, Virginia, US
Full timeBachelorsSenior levelHybridInfrastructure Engineering And Data Center Consulting5,001+ employees

Senior, primarily remote Mechanical Engineer designing HVAC and cooling systems for mission-critical data centers, with 6+ years of experience and P.E. registration required.


About this role

AECOM is seeking a senior Mechanical Engineer to design and coordinate HVAC, heat rejection, cooling, airflow, and energy-efficiency systems for data center and mission-critical projects. The role is primarily remote within the United States but includes occasional travel and mandatory in-person Day 1 onboarding. Candidates must have a bachelor's degree or equivalent education and experience, at least 6 years of relevant experience, experience with data center equipment installation and operation, and P.E. registration. U.S. employment authorization sponsorship and relocation assistance are unavailable.

Required qualifications

  • A bachelor's degree with at least 6 years of relevant experience, or demonstrated equivalent experience and education, is required.
  • Experience with data center mechanical and electrical equipment installation and operation is required.
  • Professional Engineer (P.E.) registration is required.
  • Ability to design data center heat rejection, HVAC, cooling, airflow management, redundancy, and fault-tolerant systems is required.
  • Ability to perform data center heat load calculations, capacity planning, and HVAC system coordination is required.
  • Ability to conduct or direct computational fluid dynamics (CFD) analysis and use the results to optimize data center HVAC performance is required.
  • Ability to collaborate with electrical, mechanical, and other engineering disciplines on mission-critical infrastructure projects is required.

Desired qualifications

  • A bachelor's degree in mechanical engineering, HVAC engineering, or a related field from an accredited university is preferred.
  • A master's degree or advanced coursework in HVAC systems or energy management is preferred.
  • Knowledge of Uptime Institute Tier Standard Topology, TIA-942, and ANSI/BICSI 002 is preferred.
  • Professional certifications such as Certified Energy Manager, Building Energy Modeling Professional, or LEED accreditation are advantageous.
  • Experience with data center cooling systems such as fan wall units, CRAHs, chilled water systems, DX systems, CRAC units, in-row cooling, and containment solutions is preferred.

Restrictions

  • The position is limited to candidates who can work from locations in the United States where AECOM has an office.
  • Periodic travel for client meetings, project milestones, onsite collaboration, or other business-critical activities may be required.
  • Sponsorship for U.S. employment authorization is not available now or in the future.
  • Relocation assistance is not available.
  • New hires must attend an in-person Day 1 onboarding at an AECOM office.

Similar jobs

Find your dream job with Sprout

Swipe right to apply. Let AI handle the rest.