Data Center Engineer - Critical Faciliites

Verisign

Reston, Virginia, US$109k–147k/yr
Full time$109k–147k/yrSenior levelIn personInternet Infrastructure And Technology Services501–1,000 employees

Senior onsite data center facilities engineering role requiring 7+ years of experience with critical electrical, mechanical, and fire/life safety systems.


About this role

Verisign is hiring a Senior Critical Facilities Engineer to serve as a technical leader within its Global Data Center Operations Team in Ashburn, Virginia. The role is responsible for onsite operation, maintenance, capacity planning, resiliency, escalation support, and improvement of mission-critical electrical, mechanical, and fire/life safety systems. Candidates need 7 or more years of data center operations experience, broad critical-facilities expertise, strong technical communication skills, and the ability to lead projects and remediation efforts as an individual contributor.

Required qualifications

  • At least 7 years of relevant experience operating data centers in a technical lead individual contributor role.
  • The candidate must have a deep understanding of chillers, chilled-water systems, air handlers, electrical switchgear, generators, load banks, UPS systems, STS systems, PDUs, RPPs, and batteries.
  • The candidate must have direct experience designing, engineering, commissioning, and operating data center electrical, mechanical, and fire/life safety equipment.
  • The candidate must have experience operating large-scale data center environments.
  • The candidate must understand data center tier rating systems and design risk factors related to resiliency and availability.
  • The candidate must have experience reviewing technical drawings to ensure that installations and designs conform to industry best practices and standards.
  • The candidate must have experience with Electrical Power Management Systems and Building Management Software.
  • The candidate must demonstrate strong written and verbal communication skills.
  • The candidate must be able to operate independently with limited direct management and serve as an escalation point for facility-related issues.
  • The candidate must be able to develop and use Standard Operating Procedures, Emergency Operating Procedures, and Methods of Procedure according to technical writing standards.
  • The candidate must be able to identify single points of failure and end-of-life equipment and drive remediation and prioritization efforts.
  • The candidate must be able to oversee multi-year critical facilities capacity and growth projects and develop supporting business cases.
  • The candidate must have a mechanical, electrical, or related engineering degree, or equivalent job experience.

Desired qualifications

  • Experience maintaining relationships with data center service vendors is preferred.
  • Relevant industry certifications such as NFPA, ATS, ATO, AOS, or DCDC are preferred.
  • Experience presenting root-cause findings and project recommendations to senior leadership is preferred.

Restrictions

  • This is an onsite role based at the Ashburn, Virginia data center.
  • The position is a first-shift, Monday-through-Friday role.

Similar jobs

Find your dream job with Sprout

Swipe right to apply. Let AI handle the rest.