
Sr. Field Service Engineer
Reliant Critical Infrastructure
Leads field commissioning, diagnostics, and modernization of power systems and transformers.
About this role
The Sr. Field Service Engineer leads complex commissioning, diagnostics, maintenance, and modernization of electrical power systems, with particular responsibility for transformer testing and condition assessment. The role requires senior field experience or an aligned degree with equivalent field competency, strong safety and technical expertise, crew leadership, extensive travel, and participation in on-call emergency response.
Required qualifications
- Candidates must have 11 or more years of progressively responsible field experience with MV/HV switchgear, breakers, and protection and control systems, or an aligned bachelor's or associate's degree combined with demonstrated field experience and equivalent technical competency.
- Candidates must be able to lead field crews and manage on-site execution for complex commissioning and service events.
- Candidates must have strong working knowledge of electrical safety practices, including NFPA 70E/OSHA or local equivalents, LOTO, and arc-flash risk controls.
- Candidates must be able to read, troubleshoot, and redline schematics, wiring diagrams, and one-line diagrams.
- Candidates must have demonstrated authority in transformer field testing and condition assessment, including interpreting DGA and electrical diagnostic results against IEEE C57 criteria.
- Candidates must be able to develop commissioning and test plans, verify I/O, and perform functional checks from drawings and sequences of operation.
- Candidates must be able to write clear field reports and maintain accurate test documentation.
- Candidates must maintain a valid driver's license and an acceptable motor vehicle record throughout employment.
- Candidates must be able and willing to obtain DOT non-CDL qualification, including a current DOT medical card where required, and comply with applicable DOT regulations.
Desired qualifications
- Experience commissioning digital protection relays and IEC 61850/GOOSE networks is preferred where applicable.
- Certification or formal training in SFRA, partial discharge, or other advanced transformer diagnostic methods is preferred.
- Experience leading transformer failure investigations and refurbishment or retrofit programs is preferred.
- Experience interfacing with power system studies and validating them in the field is preferred.
- Familiarity with major relay platforms and breaker OEMs is preferred.
- ANSI/NETA ETT Level 4, NICET Level IV, or OSHA 30 certification is preferred.
Restrictions
- Roles are available in Ohio, Virginia, Nevada, Texas, New Mexico, and Minnesota.
- Must be at least 21 years old to operate a company-provided service vehicle.
- Travel is typically 50–80%, may be on short notice, and can include nights, weekends, and emergency call-outs.
- Participation in the regional on-call rotation, including nights, weekends, and holidays, is required.
- Must be able to work in confined spaces, at heights, in hot or cold environments, and around rotating machinery and energized equipment.
- Must be able to wear required PPE, including arc-rated clothing and fall protection as needed.
- Must be able to lift and carry up to 50 lbs and lift up to 75 lbs with assistance.
- Must be able to stand, kneel, bend, climb ladders and stairs, and work at heights for extended periods.
- Must be able to differentiate conductor colors and indicator states and read instruments and displays.
Similar jobs
UPS Technician III
Reliant Critical Infrastructure
Atlanta, Georgia, US
Switchgear Technician
Reliant Critical Infrastructure
Ashburn, Virginia, US
Lead Critical Power Technician (UPS), Data Center
Reliant Critical Infrastructure
Shreveport, Louisiana, US
Construction Superintendent
Reliant Critical Infrastructure
Columbus, Ohio, US