
Lead Test Engineer (Power Distribution)
Trystar Inc
Cypress, Texas, US$135k–155k/yr
$135k–155k/yrBachelorsSenior levelIn personElectrical Equipment Manufacturing
Leads verification and validation testing for power distribution products and integrated systems.
About this role
The Lead Test Engineer owns design verification and validation for power distribution products and integrated systems, from concept through certification and manufacturing release. The role develops and executes test programs, coordinates laboratory, factory, and site testing, and requires a bachelor’s degree, typically 7 or more years of relevant experience, power-distribution test expertise, Python proficiency, and safe energized-testing knowledge.
Required qualifications
- A bachelor’s degree in electrical engineering or a related technical field is required.
- Typically, at least 7 years of relevant industrial experience in hands-on testing and validation of power distribution equipment is required.
- Experience with design verification and type testing of power distribution equipment, including developing test methods, plans, procedures, and reports traced to product requirements, is required.
- Working knowledge of applicable product and test standards for power distribution equipment and the National Electrical Code is required; experience with every listed standard is not required.
- Experience preparing for and conducting or witnessing tests at NRTLs or high-power laboratories is required.
- Proficiency with most of the listed power-test instruments, including power analyzers, oscilloscopes, high-voltage and current probes, thermal data acquisition, hipot and insulation resistance testers, micro-ohmmeters, TTR testers, and current injection test sets, is required.
- Proficiency with Python for test automation and data analysis is required.
- Experience planning and tracking test schedules, identifying dependencies, and communicating readiness and risks to engineering and program leadership is required.
- Working knowledge of NFPA 70E and safe practices for energized, high-voltage, and high-energy testing is required.
- Demonstrated experience leading test programs, influencing design teams, and directing technicians and engineers is required.
Desired qualifications
- A master’s degree in electrical engineering, mechanical engineering, or a related technical field is preferred.
- Experience testing medium-voltage equipment, including specified withstand, partial discharge, and internal arcing tests, and working knowledge of UL 1562 for medium-voltage dry-type transformers, is preferred.
- Experience testing DC power distribution equipment up to 1500 VDC, including 800 VDC class systems, and validating loadbanks is preferred.
- Experience with factory and site acceptance testing of power distribution centers, e-houses, or similar integrated systems, including testing to ANSI/NETA standards, is preferred.
- Experience testing power-equipment controls and communications, such as PLCs, transfer switch controllers, and Modbus, and working knowledge of UL 61010-1 and UL 61010-2-201, is preferred.
- Experience with seismic, environmental, transport, vibration, structural, and lifting validation of electrical equipment and enclosures is preferred.
- Experience with test traceability, test data logging, and test data management systems is preferred.
- Experience with data center or other critical power applications is preferred.
- NETA Level 3 or Level 4 technician certification, NFPA CESCP certification, or a Professional Engineer license is preferred.
Restrictions
- Onsite in Houston, TX; Faribault, MN; Burnsville, MN; or Charlotte, NC.
- Travel within North America up to 30%, including overnight stays.
- Work in laboratories, factories, and customer sites, including energized, high-voltage, and high-energy test areas; required PPE and site safety rules apply.
- Standing, walking, climbing, kneeling, and reaching for extended periods; lifting test equipment up to 50 pounds, using mechanical aids where required.