
Field Service Technician, Electrical Testing
Premise INC
Minneapolis, Minnesota, US$50–60/hr
Full time$50–60/hrMid levelIn personElectrical Testing And Field Services
Tests, troubleshoots, and commissions electrical systems at field sites, with regular regional travel.
About this role
Premise Inc. seeks an experienced field service technician to test, inspect, troubleshoot, and commission electrical equipment and power systems, with an initial focus on utility-scale solar and battery storage projects. The role requires at least three years of relevant hands-on experience, substantial medium-voltage and testing expertise, accurate reporting, and travel to project sites; an electrical license and several specialized certifications or testing experiences are preferred.
Required qualifications
- The candidate must have at least three years of hands-on experience in electrical testing, commissioning, power-system field service, or industrial electrical maintenance.
- The candidate must have demonstrated experience working with medium-voltage electrical systems and equipment.
- The candidate must have hands-on experience performing primary-injection testing.
- The candidate must have hands-on transformer-testing experience, including turns ratio, insulation-resistance, winding-resistance, and power-factor or Doble testing.
- The candidate must have experience testing and inspecting switchgear and circuit breakers.
- The candidate must have experience with protective-relay testing, calibration, functional testing, or settings verification.
- The candidate must be able to independently develop a testing plan, select and configure test equipment, execute tests, interpret results, troubleshoot failures, recommend corrective actions, and complete final test reports.
- The candidate must be able to interpret test data and identify equipment deficiencies or abnormal results.
- The candidate must be able to read and apply one-line diagrams, schematics, construction drawings, equipment manuals, project specifications, and test procedures.
- The candidate must be able to produce accurate test reports and turnover documentation using project-specific forms and customer requirements.
- The candidate must have working knowledge of NFPA 70E electrical-safety practices, energized-work controls, arc-flash boundaries, and lockout/tagout procedures.
- The candidate must be proficient with common electrical test instruments, such as Megger, Doble, Omicron, or equivalent equipment.
- The candidate must be able to use Microsoft Excel and electronic systems to enter test data, organize results, and prepare reports.
- The candidate must have a valid driver’s license and be able to travel to active project sites.
- The candidate must be able to work independently in the field and communicate effectively with construction, engineering, QA/QC, operations and maintenance, and project-management teams.
Desired qualifications
- NETA Level II or III certification or comparable hands-on electrical field-testing experience is preferred.
- A current electrical license issued by Minnesota, Illinois, Wisconsin, or another state is preferred.
- Experience performing VLF cable testing is preferred.
- Experience with tan delta and hipot testing is preferred.
- Experience performing grounding-system testing is preferred.
- Experience with 5 kV, 15 kV, 25 kV, 34.5 kV, or 35 kV electrical systems is preferred.
- Experience in utility-scale solar, BESS, substations, wind energy, utilities, industrial facilities, data centers, or a comparable power-distribution environment is preferred.
- Experience with SEL, GE, Schneider Electric, or comparable protective-relay and control systems is preferred.
- Experience with PowerDB, relay-testing software, manufacturer-specific test-set software, or other electronic reporting platforms is preferred.
- An associate degree in Electrical Power and Controls, Electrical Technology, or a related discipline is preferred, with relevant military power-generation or electrical training as a possible substitute.
- OSHA 10 or OSHA 30 certification is preferred.
- Current NFPA 70E training is preferred.
- CPR and First Aid certification are preferred.
- Experience leading field-testing activities or coordinating equipment-energization readiness is preferred.
Restrictions
- Valid driver’s license required.
- Must travel to project sites, including Illinois, Minnesota, and other assigned locations.
- Overnight stays may be required.
- Overtime, early starts, weekends, and outage-window work may be required.
- Must be able to lift and carry up to 50 pounds, with or without reasonable accommodation.
- Work is primarily at active construction sites and operating facilities, outdoors in varying weather and near energized or potentially energized equipment.
- Must participate in the established field-travel rotation.