Critical Facilities Engineer II

Flexential Corp.

Atlanta, Georgia, US$87k–92k/yr
Full time$87k–92k/yrSenior levelIn personData Center Infrastructure And Colocation Services

Onsite Critical Facilities Engineer II responsible for maintaining mission-critical data center electrical, mechanical, HVAC, and automation systems with 24x7 on-call coverage.


About this role

Flexential is seeking a Critical Facilities Engineer II to maintain and troubleshoot electrical, mechanical, HVAC, automation, and other mission-critical data center systems. The role is responsible for preventive and corrective maintenance, vendor management, documentation, commissioning, disaster recovery exercises, power provisioning, monitoring, compliance, and maintaining 99.999% or higher uptime. Candidates need at least two years of data center experience and four or more years in critical infrastructure and troubleshooting environments. The position is onsite, includes 24x7 on-call duties, and pays $42-$44 per hour.

Required qualifications

  • At least two years of data center experience is required.
  • At least four years of experience with root cause analysis, troubleshooting, and problem solving is required.
  • Experience working with building automation is required.
  • At least four years of experience in a critical infrastructure environment is required.
  • Candidates must understand the electrical and mechanical systems used in critical data center operations, including feeders, transformers, generators, switchgear, UPS systems, ATS units, PDU units, chillers, pumps, air handling units, and CRAH units.
  • Applicable trade experience is required.
  • Candidates must be legally authorized to work in the United States.
  • Candidates must reside and work in a state where Flexential is authorized to maintain employment registrations.
  • Candidates must possess a valid driver's license and insurance.

Desired qualifications

  • An associate degree or higher in a relevant engineering discipline is preferred.
  • Electrical or mechanical certifications are preferred.
  • Five or more years of experience working in data centers, with an emphasis on building and equipment operation, is preferred.
  • Candidates who meet or exceed the expected functional and technical depth and complexity are preferred.

Restrictions

  • The role has 24x7 facility on-call responsibility.
  • The position requires occasional off-hours and weekend maintenance activities.
  • The position requires approximately 5% travel.
  • The position requires lifting up to 50 pounds, standing or walking for approximately 50% of the time, climbing ladders, and working around electrical, chemical, mechanical, noise, temperature, and trip/fall hazards.
  • Applicants must reside and work in an eligible state; Flexential currently excludes Alaska, Alabama, Delaware, Hawaii, Iowa, Kansas, Louisiana, Maine, Maryland, North Dakota, Rhode Island, South Dakota, Wisconsin, Wyoming, and Washington, DC.
  • Applicants must be legally authorized to work in the United States; the posting does not indicate H-1B sponsorship.
  • The role is designated onsite.

Similar jobs

Find your dream job with Sprout

Swipe right to apply. Let AI handle the rest.