Critical Facilities Engineer II

Flexential Corp.

Richmond, Virginia, US$42–44/hr
Full time$42–44/hrSenior levelIn personData Center Infrastructure And Colocation Services

Onsite Critical Facilities Engineer II maintaining mission-critical data center systems, uptime, compliance, and operational reliability.


About this role

Critical Facilities Engineer II responsible for maintaining electrical, mechanical, HVAC, and other mission-critical data center infrastructure to achieve 99.999% uptime and meet customer SLAs. The role includes preventative and corrective maintenance, troubleshooting, vendor management, monitoring, documentation, commissioning, disaster recovery exercises, customer power provisioning, and training support. Candidates need at least 4 years of critical infrastructure experience and troubleshooting/root cause analysis experience, plus data center and building automation experience. The position is onsite, includes 24x7 on-call coverage, and pays $42.00-$44.00 per hour.

Required qualifications

  • At least 2 years of data center experience is required.
  • At least 4 years of experience with root cause analysis, troubleshooting, and problem solving is required.
  • At least 4 years of experience in a critical infrastructure environment is required.
  • Experience working with building automation systems is required.
  • Candidates must understand the electrical and mechanical systems used in critical data center operations, including feeders, transformers, generators, switchgear, UPS systems, ATS units, PDU units, chillers, pumps, air handling units, and CRAH units.
  • Applicable electrical, mechanical, or other relevant trade experience is required.
  • Candidates must be legally authorized to work in the United States and reside in an eligible state.
  • Candidates must possess a valid driver's license and insurance.

Desired qualifications

  • An associate degree or higher in electrical, mechanical, or a related engineering discipline is preferred.
  • Electrical or mechanical certifications are preferred.
  • At least 5 years of experience working in data centers with an emphasis on building and equipment operation is preferred.
  • Demonstrated functional and technical depth and the ability to handle complex operational requirements are preferred.

Restrictions

  • Applicants must be legally authorized to work in the United States; no visa sponsorship is indicated.
  • Applicants must reside and work in a state where Flexential maintains employment eligibility.
  • Applicants residing in or working from Alaska, Alabama, Delaware, Hawaii, Iowa, Kansas, Louisiana, Maine, Maryland, North Dakota, Rhode Island, South Dakota, Wisconsin, Wyoming, or Washington, DC are not eligible.
  • The position requires 24x7 on-call availability and occasional off-hours and weekend maintenance.
  • The role is onsite, with Atlanta-area positions potentially requiring at least 30 onsite hours per week.
  • The role involves physical demands including standing or walking 50% of the time, lifting up to 50 pounds, climbing ladders, and exposure to electrical, chemical, mechanical, noise, and temperature hazards.
  • Travel is required approximately 5% of the time.

Similar jobs

Find your dream job with Sprout

Swipe right to apply. Let AI handle the rest.